| Jenis | 3P | SD16R | SD20R | SD25R | SD32R | SD40R | SD63R | SD80R | SD80HR | SD100R | SD125R |
| 4P | |||||||||||
| Arus pemanasan yang dipersetujui (≤40°C) | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 100A | 125A | |
| Operasi dinilai IEC semasa Ie AC-21A/B (≤690V) | 16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A | |
| Arus operasi yang dinilai IEC Iaitu AC-22A/B | 415V | 16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A |
| 500V | |||||||||||
| 690V | 32A/40A | 40A/63A | 63A/80A | 63A/80A | 80A/100A | 100A/125A | |||||
| Arus operasi yang dinilai IEC Iaitu AC-23A/B | 415V | 16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A |
| 500V | 25A/25A | 63A/63A | 80A/100A | 100A/100A | |||||||
| 690V | 40A/40A | 63A/63A | 63A/63A | ||||||||
| Arus operasi yang dinilai IEC Iaitu DC-21B | 110VDC | 16A(1) | 20A(1) | 25A(1) | 32A(1) | 40A(1) | 63A(1) | 80A(1) | 100A(1) | 100A(1) | 125A(1) |
| 250VDC | 16A(2) | 20A(2) | 25A(2) | 32A(2) | 40A(2) | 63A(2) | 80A(2) | 100A(2) | 100A(2) | 125A(2) | |
| 400VDC | 16A(3) | 20A(3) | 25A(3) | 25A(3) | 40A(3) | 63A(3) | |||||
| Kuasa operasi yang dinilai IEC (3Phse) AC-23A/B | 415V | 7.5KW | 9KW | 11KW | 15KW | 18.5KW | 30KW | 37KW | 45KW | 55KW | |
| 500V | |||||||||||
| 690V | 11KW | 15KW | |||||||||
| Arus rintangan litar pintas bagi perlindungan fius (nilai jangkaan kA rms) | |||||||||||
| Kelas fius | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 125A | ||
| Bersyarat dinilai arus litar pintas | 50kA | 25kA | |||||||||
| Litar pintas menahan arus pemutus litar untuk perlindungan, mana-mana pemutus litar yang boleh terpelantik dalam masa 0.3 saat | |||||||||||
| Dinilai jangka pendek menahan arus | 2.5kA | 3kA | 5kA | ||||||||
| Prestasi litar pintas (tanpa perlindungan) | |||||||||||
| Arus tahan jangka pendek yang dinilai | 1.26kA | 1.5kA | 2.75kA | ||||||||
| Kapasiti pembuatan litar pintas yang dinilai | 1.8kA | 2.1kA | 3.9kA | ||||||||
| Kawasan rentas terminal | 1.5~16mm² | 2.5-35mm² | 10~70mm² | ||||||||
| Voltan penebat dinilai Ui | 800V | ||||||||||
| Voltan menahan impuls dinilai Uimp | 8kV | ||||||||||
| Daya Tahan Mekanikal | 100000 | ||||||||||
| Suhu Ambien | Operasi -25°C…+55°C / Penyimpanan -40°C…+70°C | ||||||||||
| (1) Setiap kutub digunakan sebagai positif dan negatif (2) Tiga kutub digunakan secara bersiri dengan kutub positif dan negatif, yang mana dua kutub bersiri, dan yang satu lagi negatif (3) Empat kutub digunakan secara bersiri dengan kutub positif dan negatif | |||||||||||