| Model | Pemutus Litar | ||||||||
| MCB | RCD | RCBO | |||||||
| 1P/2P | 3P/4P | 2P | 4P | 1P | 2P | 3P | 3P+N | 4P | |
| CJ53RAi-1-AC | √ | √ | √ | √ | |||||
| CJ53RAi-2-AC | √ | √ | √ | √ | √ | ||||
| CJ53RAix-1-AC | √ | √ | √ | √ | |||||
| CJ53RAix-2-AC | √ | √ | √ | √ | √ | ||||
| CJ53RAi-1-DC | √ | √ | √ | √ | |||||
| CJ53RAi-2-DC | √ | √ | √ | √ | √ | ||||
| CJ53RAix-1-DC | √ | √ | √ | √ | |||||
| CJ53RAix-2-DC | √ | √ | √ | √ | √ | ||||
| Ciri-ciri Elektrik | |||
| Piawai | EN 50557 | ||
| Sistem Pengagihan Kuasa | TT – TN – S | ||
| Voltan Dinilai (Ue) | (V) | 230 AC (1) | |
| Voltan Nilai Min (Ue Min) | (V) | 85% Ue | |
| Voltan Nilai Maksimum (Ue Maksimum) | (V) | 110% Ue | |
| Voltan Penebat Berkadar (Ui) | (V) | 500 | |
| Kekuatan Diaelektrik | (V) | 2500 AC selama 1 minit | |
| Voltan Tahan Nilai (Uimp) | 4 | ||
| Kategori Voltan Lebih | III | ||
| Kekerapan Dinilai | (Hz) | 50 | |
| Kapasiti Pemecahan Kebocoran Tanah (I△m) | (A) | I△c Pemutus Berkaitan | |
| Arus Litar Pintasan Baki Terkadar (I△c) | (A) | I△m bagi Pemutus Berkaitan | |
| Orang Poland | 2 | 4 | |
| Jenis MCB | 1P – 2P – 3P – 4P | ||
| Jenis RCCB | AC – A – A[IR] – A[S] | ||
| Jenis RCBO | |||
| Arus Terkadar (Masuk) | (A) | 25 – 40 – 63 – 80 – 100 | |
| Arus Baki Terkadar (I△n) | (mA) | 30 – 100 – 300 – 500 | |
| Rintangan bukan operasi dinilai antara komponen elektrik dan bumi | (kΩ) | 8 (30mA) – 2,5 (100/300/500mA) | |
| Rintangan kerja yang dinilai antara bahagian hidup dan bumi | (kΩ) | 16 (30mA) – 5 (100/300/500mA) | |
| Dalam kehilangan kuasa | (W) | Kehilangan kuasa pemutus litar berkaitan | |
| Kuasa Statik | (VA) | 1 | 1 |
| Kuasa penutupan semula automatik | (VA) | 20 | 20 |
| Ciri-ciri Mekanikal | |||
| Lebar Modul DIN | 1 | 1 | |
| Selang Masa Penutupan Semula | (s) | 10 – 60 – 300 | |
| Frekuensi Operasi Maksimum | (operasi/j) | 30 | |
| Ketahanan mekanikal maksimum (jumlah keseluruhan operasi) | 10000 | ||
| Kitaran Penutupan Semula Automatik Maks. | 60 | ||
| Nombor masa penetapan semula kaunter Penutup semula berterusan operasi | (s) | 3 | |
| Bahagian Terminal Pemutus | (mm²) | Kabel Lembut:≤ 1×35 – ≤ 2×16 – ≤ 1×16+2×10 | |
| Tork pengetatan berkadar pemutus litar | (Nm) | 3 (IDP) – 2 (IDP NA) | |
| Lokasi pemasangan | Mana-mana | ||
| Gred Perlindungan Pemutus Litar | IP20 () – IP40 () | ||
| Ciri-ciri Alam Sekitar | |||
| Gred Pencemaran | 2 | ||
| Suhu Kerja | (°C) | -25 +60 | -25 +60 |
| Suhu Penyimpanan | (°C) | -40 +70 | |
| Kelembapan Relatif | 55°C – Kanan Kiri 95% | ||
| Ciri-ciri Sentuhan Bantu | |||
| Bantuan | Ya | Ya | |
| Jenis Hubungan | - | Relay Elektronik | |
| Voltan Dinilai | (V) | - | 5-230 AC/DC |
| Arus Terkadar | (A) | - | 0.6 (min) -1 (maks) |
| Kekerapan | (Hz) | - | 50 |
| Gunakan kategori | - | AC12 | |
| Mod Operasi | - | Isyarat NO\NC\ Kedudukan Pemegang | |
| Sambungan Kabel | (mm²) | - | ≤2.5 |
| Tork Pengetatan Berkadar | (Nm) | - | 0.4 |
| Fungsi Tutup Semula Automatik | |||
| Tutup Semula Automatik Apabila Kerosakan Elektrik Terputus | √ | √ | |
| Ujian Sesar Bumi | |||
| Ujian Kebocoran Tanah | |||
| Tutup Semula Hentian Apabila Berlaku Kerosakan | √ | √ | |
| Isyarat Penutupan Semula | |||
| Penunjuk Isyarat Kerosakan | √ | √ | |
| Fungsi Auto / Manual | √ | √ | |
| Hubungan Bantu untuk Operasi Jauh | |||
| Perlindungan Elektrik Dalaman | PTC | PTC | |